Warning, Installing to interior corner wood stud wall – Peerless-AV CM850-S - Installation User Manual

Page 5

Advertising
background image

5 of 48

ISSUED: 07-22-08 SHEET #: 120-9055-3 10-05-11

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112

Wall plates (B) can be mounted to one or two studs that are 16" apart. Use a stud finder to locate the edges of
the studs. Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line
down each stud’s center on both walls. NOTE: Depending on placement of studs on wall corners, mounting to
two studs may not be possible.
Determine the distance from the corner of the wall to the inside edge of the wall plates (B) using the equation
below and detail 1 to get distance "X". NOTE: If mounting speaker mounts to sides of corner mount, display can
be no larger than 40". See page 16 for speaker mount installation.
Measure "X" distance from corner of wall and mark location for inside edge of wall plate. The top mounting slots
of wall plate should be located 3.44" (87 mm) above the desired display center as shown in fig 1.1. Level wall
plate, align to location marked for inside edge of wall plate and mark four slots in alignment with center of studs.
Repeat for opposite wall plate. Drill 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Make sure that
wall plates are level and secure using #14 x 2.5" wood screws (Q).

Installing to Interior Corner Wood Stud Wall

1

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all

attached hardware and components.

• Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is

highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.

Installers are responsible to provide hardware for other types of mounting situations.

WARNING

STUD

CS = CENTER OF DISPLAY

CS

B

fig. 1.1

B

B

Q

fig. 1.2

Y

X

X

DETAIL 1

"X" =

- 21.216

Y

1.414

3.44"

(87 mm)

Advertising