InnovOx On-Line Analyzer Details

Specifications

Operating Specifications

1

Analysis Modes

NPOC, TOC (TC-IC), TC, IC

Dynamic TOC Range

Up to 50,000 ppm TOC

TOC Limit of Detection (LOD)

0.05 ppm NPOC

TOC Accuracy**

±3%

TOC Precision**

RSD ≤ 1.5%

TOC Linearity***

R

2

≥ 0.995, measured as NPOC

Analysis Time

2.6 to 8.3 min in online mode

TOC Calibration Stability

Up to 6 months

Particle Diameters in Sample

≤ 200 µm diameter without filtration,

> 200 µm with optional Filter Panel

Ambient Temperature Range

10–40 °C (50–104 °F)

Maximum Relative Humidity

Up to 95%, non-condensing

Sample Temperature Range

10–60 °C (50–140 °F)

Sample Volume

0.6 ml to 3 ml

Sample Inlet Pressure

125 psig maximum with provided control valve

0.5 psig minimum without optional sample pump

Drain

Gravity drain

Analyzer Specifications

Outputs

External USB port (1), internal USB ports (2), Ethernet (1), Binary End-of-Analysis Output (1),

Isolated 4-20 mA Analog Outputs (5)

Display

Color, touch-sensitive LCD

Power

100–240 ±10% VAC, 280 W, 50/60 Hz

Dimensions

Analyzer: H: 92.7 cm (36.5 in); W: 64.6 cm (25.4 in); D: 38.7 cm (15.3 in)

Weight

Analyzer: 36.3 kg (80 lb)

Safety Certifications

CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 No. 61010-1.

IP Rating

IP56 (optional)

Consumables

Maintenance Frequency

Estimated Maintenance Time

Acid Reagent

As needed

5 minutes

Oxidizer Reagent

As needed

5 minutes

Reagent Grade Water

As needed

5 minutes

Pumps

12 months

15 minutes

Sample Flow Path Tubing

3 months

15 minutes

Valve Seals (2)

Up to 3 months, depending on sample matrix

15 minutes

Sample Pump Tubing (optional)

3 months

15 minutes

0

200

400

600

800

1000

1200

1400

1600

Time

To

ta

l C

ar

bo

n

(p

pm

)

Accessories and Options

Air Purifier

The Air Purifier removes CO

2

from the air so the Analyzer can

use house air as the compressed gas source.

Filter Panel

This accessory filters one sample

stream, and it is automatically

cleaned by back flushing with

compressed air. The Filter Panel is

adjustable for various particulate

levels.

Fail-Safe Accessory

Sensors detect when the flow rate of each sample stream

stops or consumables need replenishing.

IP56

The IP56 configuration protects the Analyzer from water

spray and dust that would interfere with its operation.

NEMA 4X

The NEMA 4X enclosure protects the instrument from

corrosive environments.

Other Accessories

Other accessories include a mounting stand, a sample

peristaltic pump, and multi-stream (2, 5) configurations.