5.4 ELECTROPUMP BATTERY REQUIREMENTS :

When choosing the type of batteries needed for your thruster’s battery bank, keep in mind

that it is the CCA (Cold Cranking Amps) capacity that is the most important and not the Ah
(Amp-hour) capacity. This is because thrusters draw high currents, but only for very short

periods of time (maximum 3 min.)

Max Power would recommend using Exide, Maxxima 900 type batteries, which have an

800CCA and 50Ah capacity.



-

+

12 V
800 CCA
50 Ah

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

-

+

-

+

12 V
800 CCA
50 Ah

12 V
800 CCA
50 Ah

-

+

12 V
800 CCA
50 Ah

To 24 V Electropump
Series/Parallel

To 24V Electropump
Series

Pos. ( + )

Pos. ( + )

Neg. ( - )

Neg. ( - )

OR

Minimum Battery
Bank Size

Ideal Battery
Bank Size

VIP 150 Hydraulic with 24V Electropump

If the dedicated batteries are charged by the alternator, the reference of the charge must be
taken after the diode-splitting block (if in doubt, consult a marine electrician).

If the batteries or cables are inferior to those recommended, the VIP will not reach its
potential thrust. The greater the batteries and cables size, the better the thrust.

Do not ground the VIP.

5.5 BATTERY

ISOLATOR:

A manual battery isolator, of the correct size, should be installed in the positive supply cable,

as close as possible to the thruster battery bank and should be easily accessible and clearly
marked.

An electrical battery isolator, as supplied by Max Power, may also be installed in the positive
supply cable, as close as possible to the thruster battery bank, in order to benefit from all

automatic safety features of the electronic control system.

VIP 150 Hydraulic 24V

Type of Batteries

Exide, Maxxima 900

Number of Batteries

2 to 4

Type of Connection

Series or Series/Parallel