MAX Power VIP150-HYD User Manual

Page 6

Advertising
background image

VIP 150, Hydraulic with Electronic Controller

25/12/2005

6


( a )

( b )

< 2 mm

Thrust Plate

Mounting
Base

Mounting
Base
Flange


90°

CORRECT

Water
Line

Water
Line

Not 90°

WRONG

Before fixing the thruster unit onto the mounting base flange it is important to ensure

that the top surface of the mounting base flange is perfectly flat in order to accept the

« O » ring seal of the VIP base flange in order to ensure perfect water tightness.

The bolts fixing the VIP onto the mounting flange must be inserted from top to bottom.

Provide sufficient access underneath the flange to allow for tightening the nuts. If the
access is not possible, provide a special mounting flange with metric studs or tapped

holes.

The VIP pushes its thrust plate sideways
against the inside of the mounting base

when running. This means that one must

totally lower the unit and check the
following:

(a)

That the VIP’s thrust plate is free to

move up and down.

(b)

And also that there is no more than
2mm horizontal movement

between the thrust plate and the

mounting base, especially when
fully down.

The mounting base

flange should be parallel
to the waterline.

In other words the
thruster unit must be

installed vertical with its

turbine totally clear of
the hull in the down

position.

Advertising