2 control unit (css), 3 i/o extension board, 2 control voltage transformer – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Select Service Manual User Manual

Page 16

Advertising
background image

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319

16/46

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

4.1.2 Control unit (CSS)

Control unit (CSS) includes a control board with five board slots for option boards and a control keypad
for parameter adjustments. Inverter uses only one of the existing slots and is used to connect I/O
extension board. The CSS is connected to PSS through a connector.

Green

Red

Status

ON OFF Everything

is

OK.

blinking

ON

Fault

blinking

blinking

In process of software downloading

RED

GREEN

K

E

Y

P

A

D

I/O

E

xt

en

si

on

B

oa

rd

ANALOG TERMINAL

ROA1

A

B

C

D

ANALOG TERMINAL

4.1.3 I/O Extension board

NXOPTB9 / I/O Extension board

ID: 52305691

Terminal

Signal name

Description

1 DID1

42-240Vac

50/60Hz

2 DID2

42-240Vac

50/60Hz

3 DID3

42-240Vac

50/60Hz

4 DID4

42-240Vac

50/60Hz

5 DID5

42-240Vac

50/60Hz

6

COM

Common for DID1-DID5


7


ROD1

8 ROD1

Relay output, 250V 8A, normal open
For brake contactor control

LED Blinking

Status

Yellow 0.25Hz OK
Yellow 4Hz

Board internal fault or communication fault with control
unit

YELLOW

1

2

3

4

5

6

7

8

4.2 Control voltage transformer

Power of control voltage transformer has to be n * 50VA + 50VA (min. 250VA), n = number of inverters.
This power does not have to be added to otherwise needed transformer power.

Advertising