Analog-series, Analog series, Dc power supplies – Powersolve Short Form Catalogue User Manual

Page 14

Advertising
background image

DELTA ELEKTRONIKA

DC POWER SUPPLIES

24

For full

specifications

and order information please visit

www.deltapowersupplies.com

analog

Series

analog interFaCeS

Specifications

•

Programming and monitoring offset : +/- 60 µV typical

•

Full scale error

: 0.1% calibrated

•

Non-linearity

: 0.01% typical, TC = - 65ppm/°C

•

Common mode rejection

: 80 dB @ 50 Hz

Features

•

Selectable 0-5 V and 0-10 V signal levels

•

Isolated programming and monitoring of U, I and status signals

•

Prevents problems with earth loops and CM-voltages

•

Factory installed or external module

•

Reinforced safety insulation 1000 VDC*

* External module has Basic insulation only

Unit

ISO AMP

Isolated Analog Programming

Specifications

•

Programming and monitoring offset : +/- 60 µV typical

•

Full scale error

: 0.1% calibrated

•

Non-linearity

: 0.01% typical, TC = - 65ppm/°C

•

Common mode rejection

: 80 dB @ 50 Hz

Features

•

Connecting SM3000 and ES-series in M/S series mode

•

Equal voltage sharing in series operation

•

Series operation possible up to 600 V

Unit

M / S - ADAPTER

Master / Slave Series Adapter

Specifications

•

Undervoltage range : 18-48 V

•

Overvoltage range : 24-64 V

•

Insulation between circuits : 500 V DC

•

Alarm contact : 100 mA / 30 V, Normally Closed

Features

•

Large adjustment for use on both 24 V and 48 V

•

Two isolated comparator circuits with alarm contact and LED indication

•

Monitors output voltage of 2 power supplies

Unit

AL 24-48

Under and Over Voltage Alarm

Advertising