4. Grounding variations


The patch panel is terminated with 4 Sub-D connectors each of them corresponding to groups
(Sub-D groups) of 12 channels. Each Sub–D connector has only two ground contacts:

• one for the top row connecting all top row ground contacts

• one for the bottom row connecting all bottom row ground contacts


Each Sub-D group is configured by its own jumper block. The flexible grounding system
provides the following alternatives to choose from:

Chassis Common:

All channel grounds (top & bottom row) are
connected via PCB and jumpers to the patch panel
chassis as standard (delivery configuration).


Sub-D-Group-Central:

Ground contacts of top and bottom row are
connected but separated from chassis.


Sub-D-Group-Chassis Top or Bottom: Either top or bottom ground contacts are connected

to chassis.


Floating of individual channels:

The ground contacts of top and/ or bottom
jacks of each channel can be disconnected
from a Sub-D Group by cutting the tracks
between the corresponding solder pads.