INSTALLATION AND OPERATING INSTRUCTIONS


UNCRATING AND PLACING DRYER

Tools Required: 3/4" hex socket & ratchet driver, wood block 4" or 5" thick, a knife and a
groove joint pliers, which will open to 1 3/8".

1. Remove and discard packaging.

2. The crate base is attached to the dryer by (4) cap screws driven upward from below the crate

base. Remove crate base from dryer, by tipping dryer sidewise and place block under crate
base rail in center of dryer. Using a ratchet and 3/4" hex socket, remove and discard (2)
crating bolts from side, which is raised. Remove block from under crate base. Repeat for
other side.


3. Install leveling legs. Using a walking motion, move dryer sideways about 6" off crate base.

Tip dryer up and place block under edge of dryer. Thread two leveling legs about two-thirds
into the T-nuts on the base from which the crating bolts were removed. Remove block from
under dryer.

With a walking motion move dryer completely off crate base. Discard crate base.

Tip dryer sidewise, as previously done, and place block under edge of dryer on raised side.
Thread leveling legs into nuts as was done for the first side.

Slide unit into position where it will be installed. Adjust leveling legs, using the groove joint
pliers, to level and align dryer with adjacent units.

DRYER INSTALLATION

1. CODE CONFORMITY. All commercial dryer installations must conform with local codes

or, in the absence of local codes, with the latest edition of the National Fuel Gas Code ANSI
Z223.1A Canadian installations must comply with current Standard CAN/CGA-B1 49(.1 or
.2) Installation Code for Gas Burning Appliances or Equipment, and local codes if
applicable. The appliance, when installed, must be electrically grounded in accordance with
the latest edition of the National Electrical Code, ANSI/NFPA70, or, when installed in
Canada, with Standard CSA C22.1 Canadian Electrical Code Part 1.


2. INSTALLATION CLEARANCES: This unit may be installed at the following alcove

clearances.

I Left

side 0"

II Right

side 0"

III Back

18" [457] (Certified for 6" [25] clearance; however, 18" [457] clearance is
necessary

behind the belt guard to allow for servicing and maintenance)

IV Front

48" [1219] to allow use of dryer.