SENA Parani100 User Manual
Page 28
![background image](/manuals/292702/28/background.png)
- 28 -
28
•
Host Port Number
For Server Host port no. entry
•
Re-connect automatically if link is lost.
For Host connect retry, if failed.
Retry frequency is set in the preceding function.
•
Try to Connect to Server every [] ms
When Parani100 fails to open a data channel connecting to Host, enter the connection
retry frequency. Entering 0 [zero] obtains retry abort.
C) Vertex Mode
Parani100 Vertex Mode avails Wireless RS485 multidrop service when assigned at
this site.
<Configuration of Vertex Mode>
•
Vertex Port
For Parani100 Vertex port no. entry.
•
Max Number of Connections
For entering the number of Hosts connectable to Parani100.
D) Repeater Mode
In Repeater Mode, Parani100 will act as a Repeater to expand the coverage of
Bluetooth. Let’s call the Parani100 that will act as Repeater, “Repeater”, and call the
Parani100 of normal operation as “Station”.
In Repeater Mode, configuration required is only the Address of the Station Parani100.
When Repeater is connecting the Station, Status LED of Repeater is blinking.