C.6 tcp server mode operation troubleshooting, C.7 serial communication troubleshooting – SENA NEMO10-SK User Manual

Page 52

Advertising
background image

51

C.6 TCP Server Mode Operation Troubleshooting

Problem

Cause

Action

IP configuration of
remote host is invalid

Check if IP configuration of the remote host is valid

Host mode of the
NEMO10 serial port is
not TCP server

Change the host mode of the NEMO10 serial port to TCP server
or TCP server/client

IP address of the
NEMO10 or TCP port
number is wrong

Specify valid IP address and TCP port number of the NEMO10

DSR option is set but
DSR input is not high

Disable DSR option or make DSR input of the NEMO10 high

Cannot connect to
the NEMO10

TCP connection with
the other host is
established already

Close established TCP connection or connect later

C.7 Serial Communication Troubleshooting

Problem

Cause

Action

Serial data are not
transferred by
TCP/IP immediately

Too large inter-character
timeout

Set inter-character timeout with smaller value

Cannot
communicate with
the NEMO10

Invalid serial port
configuration

Check if serial port configuration of the NEMO10 are the same
with that of the serial device

Invalid data
transferred

Invalid serial port
configuration

Check if serial port configuration is correct.