Figure 7. connectors, Figure 6. nut, Figure 5. motor cam – GE Industrial Solutions EntelliGuard G Spring charge Contact User Manual

Page 2: Figure 4. screws

Advertising
background image



4. Disconnect the input wire assembly plugs for
the motor and the spring charge status indicator

switch as shown in fig.7.

Figure 7. Connectors

6. Remove the M8 nylock nut from the end of the
camshaft.

Figure 6. Nut

7. Remove the cam from the cam drive shaft.

Figure 5. Motor cam

8. Take out the motor operator which is aligned
on the 3 mounting holes in the side sheet by
rotating it and removing three M5 bolts from the
gearbox endplate.

Figure 4. Screws


9. Replace the existing spring charge contact
assembly with the new assembly by removing the
two screws.


Figure 1. (A) Front Cover (B) ScrewRemoval (C) Handle
Rotation

10. Re-assemble the motor operator. Refer DEH-

41413 for the sequence of the steps.





2

Advertising