Ge energy, 6a austin microlynx, Ii: non-isolated dc-dc power modules – GE Industrial Solutions 6A Austin MicroLynx II User Manual

Page 2: Data sheet, Absolute maximum ratings, Electrical specifications

Advertising
background image

GE Energy

Data Sheet

6A Austin MicroLynx

TM

II: Non-Isolated DC-DC Power Modules

8.3Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 6A Output Current

October 16, 2012

©2012 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 15 Vdc

Continuous

Sequencing voltage

All

Vseq

-0.3

V

IN,max

Vdc

Operating Ambient Temperature

All

T

A

-40 85 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

V

o,set

≤ 3.63

V

IN

8.3 12 14 Vdc

V

o,set

> 3.63

V

IN

8.3 12 13.2

Vdc

Maximum Input Current

All

I

IN,max

4.5

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

)

Input No Load Current

V

O,set

= 0.75 Vdc

I

IN,No load

17

mA

(V

IN

= V

IN, nom

, Io = 0, module enabled)

V

O,set

= 5.0Vdc

I

IN,No load

100

mA

Input Stand-by Current

All

I

IN,stand-by

1.2

mA

(V

IN

= V

IN, nom

, module disabled)

Inrush Transient

All

I

2

t

0.4 A

2

s

Input Reflected Ripple Current, peak-to-peak

(5Hz to 20MHz, 1μH source impedance; V

IN, min

to V

IN,

max,

I

O

= I

Omax

; See Test configuration section)

All

30

mAp-p

Input Ripple Rejection (120Hz)

All

30

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a
complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety
and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 6 A
(see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input
current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.

Advertising