Seite2, Entelliguard g – GE Industrial Solutions EntelliGuard G IP54 Cover User Manual
Page 2
Each EntelliGuard breaker is supplied with a Door 
Frame that provides the installed device with an 
IP40 rating. Optionally an extra cover is available 
providing an IP54 rating.
It can be fitted on the panel door in place of the 
door flange. It uses the same hole pattern as door 
flange and doesn't require any additional holes. 
Use the following procedure to install the IP54 cover 
on the panel door.
1. Check that the package contains all the parts 
listed in Table.
2. Turn the breaker off and discharge the closing 
springs by depressing the OFF and ON buttons in 
the sequence OFF-ON-OFF.
Verify that the breaker OFF-ON indicator shows OFF 
on a green background and that the charge indicator 
shows DISCHARGE on a white background.
3. Open the panel door. Remove the door flange 
from the door by removing the screws from inside 
of the door.
4. Assemble the IP54 cover assembly on the door 
with screws and washers as shown in picture. 
5. 12 screws are required to assemble the IP54 
cover for a drawout type of breaker.
6. 10 screws are required to assemble the IP54 
cover for a fixed type of breaker.
7. Fixed type of IP54 cover needs an additional 
bracket assembly as shown in the Fig.4.
8. For opening the cover, rotate the latch in anti-
clock wise direction
9. For locking the door, rotate the latch in clock-
wise direction.
Jeder Leistungsschalter wird mit einem Türrahmen 
für Schutzart IP40 ausgeliefert. Eine separat 
lieferbare IP54-Abdeckung ist für alle 
Schaltergrößen verfügbar. Sie kann auf der 
Schranktür an die Stelle der Türrahmen angebaut 
werden. Sie verwendet die gleichen Löcher wie die 
Türrahmen und erfordert keine zusätzlichen Löcher.
Gehen Sie wie folgt vor, um die IP54 Abdeckung auf 
der Schranktür zu installieren.
1. Prüfen Sie, ob der Verpackungsinhalt mit den 
Angaben der Tabelle übereinstimmt.
2. Schalten Sie den Leistungsschalter aus und 
entspannen Sie die Antriebsfedern durch die 
Betätigung der OFF (AUS) und ON (EIN)-Tasten in der 
Reihenfolge OFF-ON-OFF (AUS-EIN-AUS). 
Überprüfen Sie, dass die Leistungsschalter OFF-ON-
OFF-Anzeige nun einen grünen Hintergrund und die 
Antriebsfeder-Anzeige DISCHARGED (ENTSPANNT) 
auf einem weißen Hintergrund anzeigt.
3. Öffnen Sie die Schranktür. Entfernen Sie die 
Türrahmen von der Tür, indem Sie die Schrauben 
aus dem Türinneren entfernen.
4. Setzen Sie die IP54 Abdeckung auf die Tür mit 
Schrauben und Unterlegscheiben, wie in Bild 
gezeigt.
5. 12 Schrauben sind erforderlich, um die IP54 
Abdeckung für einen Einschubtechnik-
Leistungsschalter einzubauen.
6. 10 Schrauben sind erforderlich, um die IP54 
Abdeckung für Festeinbau-Leistungsschalter zu 
montieren.
7. Festeinbautypen mit IP54 Abdeckungen 
benötigen eine zusätzliche Halterung wie sie in der 
Abbildung 4 gezeigt wird.
8. Zum Öffnen der IP54 Abdeckung, drehen Sie die 
Verriegelungsschraube gegen den Uhrzeigersinn.
9. Zum Verriegeln der Tür, drehen Sie die 
Verriegelungsschraube im Uhrzeigersinn.
IP54 Cover
IP54 Schutzabdeckung
Osłona IP54
EntelliGuard G
Deutsch
Polish
Catalogue number |
-------------------------------------------------------------------
IP54 Cover G54DR
IP54 Schutzabdeckung G54DR
G54DR
Katalognummer | Numer katalogowy
Osłona IP54
Tabela: Wykaz części
Opis:
Ilość
-----------------------------------------------------------
Osłona IP54
1
Nakrętka sześciokątna M4
2
Śruby M4 x 10
12
Podkładka zwykła M4
12
Podkładka zabezpieczająca M4
12
Wspornik montażowy
1
A
B
C
Table: Part list
Description:
Quantity
------------------------------------------------------------
Cover Assembly
1
M4 Hex nut
2
Screws M4 x 10
12
Plain washer M4
12
Lock washer M4
12
Mounting bracket
1
A
B
C
1
Tabelle: Teileliste
Beschreibung:
Anzahl
------------------------------------------------------------
Abdeckung
1
M4 Mutter
2
Schrauben M4 x 10
12
Unterlegscheiben M4
12
Federringe M4
12
Montageklammer
1
A
B
C
Każdy wyłącznik EntelliGuard jest dostarczany z 
ramką do zamocowania na drzwiach rozdzielnicy, 
zapewniającą zainstalowanemu wyłącznikowi 
stopień ochrony IP40. Opcjonalnie można 
zastosować dodatkową osłonę zapewniającą 
stopień ochrony IP54. 
Osłona może być zamocowana na drzwiach 
rozdzielnicy zamiast ramki. Rozmieszczenie 
otworów montażowych jest identyczne jak dla 
ramki, dodatkowe otwory nie są potrzebne. 
Zamocowanie osłony IP54 na drzwiach rozdzielnicy 
należy wykonać w sposób opisany poniżej. 
1. Sprawdzić, czy opakowanie zawiera wszystkie 
elementy podane w Tabeli.
2. Otworzyć wyłącznik i rozbroić (rozluźnić) 
sprężyny zamykające wciskając przyciski OFF i ON 
w kolejności OFF-ON-OFF. 
Sprawdzić, czy wskaźnik OFF-ON wyłącznika 
sygnalizuje pozycję OFF(wyłącznik otwarty) na 
zielonym tle i czy wskaźnik zazbrojenia wskazuje 
DISCHARGE (rozbrojony) na białym tle. 
3. Otworzyć drzwi rozdzielnicy. Zdjąć kołnierz 
(ramkę) z drzwi poprzez odkręcenie śrub na 
wewnętrznej stronie drzwi. 
4. Zamocować osłonę IP54 na drzwiach używając 
śrub z podkładkami, zgodnie z rysunkiem. 
5. Do zamocowania osłony IP54 dla wyłącznika 
wysuwnego należy użyć 12 śrub. 
6. Do zamocowania osłony IP54 dla wyłącznika 
stacjonarnego należy użyć 10 śrub. 
7. Osłona IP 54 dla wyłącznika stacjonarnego 
wymaga użycia dodatkowego wspornika 
przedstawionego na Rys. 4. 
8. Aby otworzyć osłonę należy obrócić zamek w 
lewo (przeciwnie do ruchu wskazówek zegara). 
9. Aby zamknąć osłonę należy obrócić zamek w 