Electrical specifications (continued), General specifications, Electrical specifications – GE Industrial Solutions Austin MicroLynx II 12V SIP User Manual
Page 4: Data sheet, Austin microlynx, Continued)
Data Sheet
January 18, 2010
Austin MicroLynx
II
TM
12V SIP Non-isolated Power Modules:
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 6A output current
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic
Load
Response
(dIo/dt=2.5A/
μs; V V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
50
⎯
mV
Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
(dIo/dt=2.5A/
μs; V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
50
⎯
mV
Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
General Specifications
Parameter
Min
Typ
Max
Unit
Calculated MTBF (I
O
=I
O, max
, T
A
=25°C)
per Telecordia SR-332 Issue 1: Method 1 Case 3
15,371,900 Hours
Weight
⎯
2.8 (0.1)
⎯
g (oz.)
LINEAGE
POWER
4