Data Sheet
October 1, 2009
Austin SuperLynx
TM
II
12V SIP Non-isolated Power Modules:
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output;16A output current
LINEAGE
POWER
4
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic
Load
Response
(dIo/dt=2.5A/
μs; V V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
100
⎯
mV
Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
(dIo/dt=2.5A/
μs; V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
100
⎯
mV
Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
50
⎯
μs
General Specifications
Parameter
Min
Typ
Max
Unit
Calculated MTBF (I
O
=I
O, max
, T
A
=25°C) 9,230,550
Hours
Telecordia SR-332 Issue 1: Method 1 Case 3
Weight
⎯
5.6 (0.2)
⎯