List of figures – GE Industrial Solutions Entelliguard TU, MicroVersaTrip Plus and PM Conversion Kits User Manual

Page 3

Advertising
background image

3

LIST OF FIGURES

1. Primary disconnects removed from the lower studs, showing the original current sensors

(LA-1600 shown)....................................................................................................................................Page 5

1a. Primary disconnects removed from the lower studs, showing the original current sensors

(RL-2000 shown) . ..................................................................................................................................Page 5

2. Original flux shifter and trip unit (Type LTS1 shown) mounting locations (LA-1600

shown)....................................................................................................................................................Page 5

3. Components supplied with the conversion kit. ..................................................................................Page 6

4. Flux shifter assembly. ......................................................................................................................Pages 7-8

5. Flux shifter mounting area. ..................................................................................................................Page 8

6. Flux shifter assembly installed, as viewed from the bottom of the breaker (RL-1600

shown)....................................................................................................................................................Page 8

7. Flux shifter assembly installed, as viewed from the bottom of the breaker (LA-Gold-1600

shown)....................................................................................................................................................Page 8

8. 36-pin trip unit connector......................................................................................................................Page 9

9. 36-pin connector adapter bracket. .......................................................................................................Page 9

10. Adapter bracket locking tabs................................................................................................................Page 9

11. Installing the push nuts onto the guide pins.....................................................................................Page 10

12. Locking tabs on mounting plate.........................................................................................................Page 10

13. Trip unit mounting plate attached to the support bracket...............................................................Page 11

14. Mounting plate and support bracket mounted on the breaker (shown without trip unit

installed).. .............................................................................................................................................Page 11

14a. Mounting plate and support bracket with trip unit (shown on RL-2000). ......................................Page 11

15. Installing the CTs on an LA-600, LA-800 or RL800 breaker..............................................................Page 12

16a. Installing the CTs on an LA-1600 breaker..........................................................................................Page 12

16b. Installing the CTs on an RL-1600 breaker..........................................................................................Page 12

16c. Installing the CTs on an RL-2000 breaker..........................................................................................Page 13

17. Caution label to be applied to the breaker and compartment door. ..............................................Page 13

18. Trip unit installed on the breaker (RL-1600 shown). ........................................................................Page 14

19. Neutral sensor outline for 600A and 800A breakers. .......................................................................Page 15

20. Neutral sensor outline for 1600A and 2000A breakers. ...................................................................Page 15

21. Cabling diagram for MicroVersaTrip Plus™ and MicroVersaTrip PM™ trip units with

ground fault on four-wire loads .........................................................................................................Page 18

Advertising