Data sheet, Thermal considerations (continued) – GE Industrial Solutions EHHD006A0B Hammerhead Series User Manual

Page 9

Advertising
background image

GE

Data Sheet

EHHD006A0B Hammerhead Series; DC-DC Converter Power Modules

18-75Vdc Input; 12Vdc, 6.0A, 72W Output

July 12, 2013

©2012 General Electric Company. All rights reserved.

Page 9

Thermal Considerations (continued)

The thermal reference points, T

ref

,

used in the specifications

for open frame modules is shown in Figure 13. For reliable
operation, these temperatures should not exceed 125

o

C.

Figure 13. T

ref

Temperature Measurement Locations for

Open Frame Module.


The thermal reference point, T

ref

,

used in the specifications

for modules with a heat plate is shown in Figure 14. For
reliable operation, this temperature should not exceed
115

O

C.

Figure 14. T

ref

Temperature Measurement Location for

Module with Heat plate.

Heat Transfer via Convection

Increased airflow over the module enhances the heat
transfer via convection. Derating curves showing the
maximum output current that can be delivered by
each module versus local ambient temperature (T

A

)

for natural convection and up to 2m/s (400 ft./min) forced
airflow are shown in Figures 15 - 18.

OUT

PUT

C

U

RR

EN

T, I

O

(A)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 15. Output Current Derating for the Open Frame
Module; Airflow in the Transverse Direction from V

out

(-) to

V

out

(+); V

IN

=48.

O

U

TP

UT CURR

ENT, I

O

(A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 16. Output Current Derating for the Module with
Heat plate; Airflow in the Transverse Direction from V

out

(-)

to V

out

(+);V

IN

=48V.

OUTPUT CURRENT

, I

O

(A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 17. Output Current Derating for the Open Frame
Module; Airflow in the Transverse Direction from V

out

(-) to

V

out

(+); V

IN

=24V.

AIRFLOW

AIRFLOW