Picotlynx, 6a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions PicoTLynx 6A User Manual
Page 12: Safety considerations
GE
Data Sheet
PicoTLynx
TM
6A: Non-Isolated DC-DC Power Modules
2.4Vdc –5.5Vdc input; 0.6Vdc to 3.63Vdc output; 6A Output Current
September 11, 2013
©2013 General Electric Company. All rights reserved.
Page 12
be a need to further reduce the output ripple and noise of the 
module. Second, the dynamic response characteristics may need 
to be customized to a particular load step change. 
 
To reduce the output ripple and improve the dynamic response 
to a step load change, additional capacitance at the output can 
be used. Low ESR polymer and ceramic capacitors are 
recommended to improve the dynamic response of the module. 
Figure 36 provides output ripple information for different 
external capacitance values at various Vo and for load currents 
of 6A while maintaining an input voltage of 5V. Fig 37 shows the 
performance with a 3.3V input. For stable operation of the 
module, limit the capacitance to less than the maximum output 
capacitance as specified in the electrical specification table. 
Optimal performance of the module can be achieved by using 
the Tunable Loop
TM
feature described later in this data sheet.
0
5
10
15
20
25
0.5
1
1.5
2
2.5
3
3.5
Output Voltage(Volts)
R
ippl
e(
m
V
p-
p)
1x10uF External Cap
1x47uF External Cap
2x47uF External Cap
4x47uF External Cap
Figure 36. Output ripple voltage for various output voltages
with external 1x10 µF, 1x47 µF, 2x47 µF or 4x47 µF ceramic 
capacitors at the output (6A load). Input voltage is 5V. 
0
5
10
15
20
0.5
1
1.5
2
2.5
3
Output Voltage(Volts)
R
ippl
e
(m
V
p-
p)
1x10uF External Cap
1x47uF External Cap
2x47uF External Cap
4x47uF External Cap
Figure 37. Output ripple voltage for various output voltages
with external 1x10 µF, 1x47 µF, 2x47 µF or 4x47 µF ceramic 
capacitors at the output (6A load). Input voltage is 3.3V. 
 
 
Safety Considerations
For safety agency approval the power module must be 
installed in compliance with the spacing and separation 
requirements of the end-use safety agency standards, i.e., UL 
60950-1, CSA C22.2 No. 60950-1-03, and VDE 0850:2001-12 
(EN60950-1) Licensed. 
For the converter output to be considered meeting the 
requirements of safety extra-low voltage (SELV), the input must 
meet SELV requirements. The power module has extra-low 
voltage (ELV) outputs when all inputs are ELV. 
The input to these units is to be provided with a fast-acting 
fuse with a maximum rating of 6A in the positive input lead
.