Safety considerations, Feature descriptions – GE Industrial Solutions NQR002A0X4 User Manual
Page 13
Preliminary Data Sheet 
February 28, 2012
NQR002A0X4: Non-Isolated DC-DC Power Modules
3 – 14Vdc input; 0.6Vdc to 5.5Vdc Output; 2A output current
 
 
LINEAGE
POWER
13
 
 
 
 
 
 
 
Figure 5. Output ripple voltage for various output 
voltages with external 1x10 µF, 1x47 µF, 2x47 µF or 
4x47 µF ceramic capacitors at the output (2A load). 
Input voltage is 12V. 
 
Safety Considerations
For safety agency approval the power module must be 
installed in compliance with the spacing and separation 
requirements of the end-use safety agency standards, 
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE 
0850:2001-12 (EN60950-1) Licensed. 
For the converter output to be considered meeting the 
requirements of safety extra-low voltage (SELV), the 
input must meet SELV requirements. The power 
module has extra-low voltage (ELV) outputs when all 
inputs are ELV. 
An input fuse for the module is recommended. Due to 
the wide input voltage and output voltage ranges of the 
module, a 4A, 125Vdc fast acting fuse is recommended 
Feature Descriptions
Enable (Remote On/Off)
The NQR002A0X4 2A power modules feature a Enable 
pin with positive logic for remote On/Off operation. If the 
Enable pin is not being used, leave the pin open (the 
module will be ON). The Enable signal (V
On/Off
) is
referenced to ground. During a Logic High on the 
Enable pin, the module remains ON. During Logic-Low, 
the module is turned OFF. 
 
Figure 6. Remote On/Off Implementation(positive 
logic). 
 
Overcurrent Protection
To provide protection in a fault (output overload) 
condition, the unit is equipped with internal 
current-limiting circuitry and can endure current limiting 
continuously. At the point of current-limit inception, the 
unit enters hiccup mode. The unit operates normally 
once the output current is brought back into its specified 
range. The average output current during hiccup is 10% 
I
O, max
.
Overtemperature Protection
To provide protection in a fault condition, these modules 
are equipped with a thermal shutdown circuit. The unit 
will shut down if the overtemperature threshold of 130ºC 
is exceeded at the thermal reference point T
ref
. The
thermal shutdown is not intended as a guarantee that 
the unit will survive temperatures beyond its rating. 
Once the unit goes into thermal shutdown it will then 
wait to cool before attempting to restart.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout 
limit, the module operation is disabled. The module will 
begin to operate at an input voltage above the 
undervoltage lockout turn-on threshold. 
Q1
VIN+
GND
+
PWM Enable
ON/OFF
V
ON/OFF
_
MODULE
I
Rpullup
ON/OFF
10K
Q2
10K
20K
20K
Q3
10K
10K