Data Sheet
December 6, 2010

Naos Raptor 6A: Non-isolated DC-DC Power Modules

4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 6A output current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 15 Vdc

Continuous

Operating Ambient Temperature

All

T

A

-40 85 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

4.5 12 14 Vdc

Maximum Input Current

All

I

IN,max

5.5

Adc

(V

IN

=4.5V to 14V, I

O

=I

O, max

)

Input No Load Current

(V

IN

= 9Vdc, I

O

= 0, module ON)

V

O,set

= 0.6 Vdc

I

IN,No load

30

mA

(V

IN

= 12Vdc, I

O

= 0, module ON)

V

O,set

= 5.0Vdc

I

IN,No load

50

mA

Input Stand-by Current

All

I

IN,stand-by

1

mA

(V

IN

= 12Vdc, module disabled)

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN

=0 to

14V

,

I

O

= I

Omax

; See Test Configurations)

All

35

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

Advertising