Feature description – GE Industrial Solutions KW010-015-020-025 (Sixteenth-Brick) User Manual
Page 13
Data Sheet
October 7, 2013
KW010/015/020/025 Series Power Modules:
36
– 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current
LINEAGE
POWER
13
Feature Description
Remote On/Off
Two remote on/off options are available. Positive logic 
turns the module on during a logic high voltage on the 
ON/OFF pin, and off during a logic low. Negative logic 
remote On/Off, device code suffix “1”, turns the 
module off during a logic high and on during a logic 
low. 
ON/OFF
Vin+
Vin-
I
on/off
V
on/off
Vout+
TRIM
Vout-
Figure 40. Remote On/Off Implementation.
To turn the power module on and off, the user must 
supply a switch (open collector or equivalent) to 
control the voltage (V
on/off
) between the ON/OFF
terminal and the V
IN
(-) terminal (see Figure 40). Logic
low is 0V
≤ V
on/off
≤ 1.2V. The maximum I
on/off
during a
logic low is 1mA, the switch should be maintain a 
logic low level whilst sinking this current. 
During a logic high, the typical maximum V
on/off
generated by the module is 15V, and the maximum 
allowable leakage current at V
on/off
= 5V is 1μA.
If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open. 
For negative logic, short the ON/OFF pin to V
IN
(-).
Remote Sense
Remote sense minimizes the effects of distribution 
losses by regulating the voltage at the remote-sense 
connections (See Figure 41). The voltage between 
the remote-sense pins and the output terminals must 
not exceed the output voltage sense range given in 
the Feature Specifications table: 
[VO(+)
– VO(–)] – [SENSE(+) – SENSE(–)]
0.5 V
Although the output voltage can be increased by both 
the remote sense and by the trim, the maximum 
increase for the output voltage is not the sum of both. 
The maximum increase is the larger of either the 
remote sense or the trim. 
The amount of power delivered by the module is 
defined as the voltage at the output terminals 
multiplied by the output current. When using remote 
sense and trim, the output voltage of the module can 
be increased, which at the same output current would 
increase the power output of the module. Care should 
be taken to ensure that the maximum output power of 
the module remains at or below the maximum rated 
power (Maximum rated power = Vo,set x Io,max).
V
O
(+)
SENSE(+)
SENSE(
–)
V
O
(
–)
V
I
(+)
V
I
(-)
I
O
LOAD
CONTACT AND
DISTRIBUTION LOSSES
SUPPLY
I
I
CONTACT
RESISTANCE
Figure 41. Circuit Configuration for remote 
sense .
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout 
limit, the module operation is disabled. The module 
will only begin to operate once the input voltage is 
raised above the undervoltage lockout turn-on 
threshold, V
UV/ON
.
Once operating, the module will continue to operate 
until the input voltage is taken below the undervoltage 
turn-off threshold, V
UV/OFF
.
Overtemperature Protection
To provide protection under certain fault conditions, 
the unit is equipped with a thermal shutdown circuit. 
The unit will shutdown if the thermal reference point 
Tref (Figure 43), exceeds 125
o
C (typical), but the
thermal shutdown is not intended as a guarantee that 
the unit will survive temperatures beyond its rating. 
The module can be restarted by cycling the dc input 
power for at least one second or by toggling the 
remote on/off signal for at least one second. If the 
auto-restart option (4) is ordered, the module will 
automatically restart upon cool-down to a safe 
temperature. 
Output Overvoltage Protection
The output over voltage protection scheme of the 
modules has an independent over voltage loop to 
prevent single point of failure. This protection feature 
latches in the event of over voltage across the output. 
Cycling the on/off pin or input voltage resets the 
latching protection feature. If the auto-restart option 
(4) is ordered, the module will automatically restart 
upon an internally programmed time elapsing. 
Overcurrent Protection
To provide protection in a fault (output overload) 
condition, the unit is equipped with internal