2 × 12a digital dual microdlynx, Non-isolated dc-dc power modules, Datasheet – GE Industrial Solutions 2 × 12A Digital Dual Output MicroDLynx User Manual
Page 25
GE
Datasheet
2 × 12A Digital Dual MicroDlynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc –14.4Vdc input; 0.51Vdc to 5.5Vdc output; 2 × 12A Output Current
February 14, 2014
©2014 General Electric Corporation. All rights reserved.
Page 25
Hex
Code
Command
Brief Description
Non-Volatile
Memory Storage
38 IOUT_CAL_GAIN
Returns the value of the gain correction term used to correct the measured
output current
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r/w
Function
Exponent Mantissa
Default Value
1 0 0 0 1 0 0 V
Bit Position
7 6 5 4 3 2 1 0
Access
r/w r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
V: Variable based on factory calibration
YES
39 IOUT_CAL_OFFSET
Returns the value of the offset correction used to correct the measured output
current
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r/w
r r
Function
Exponent Mantissa
Default Value
1 1 1 0 0 V V V
Bit Position
7 6 5 4 3 2 1 0
Access
r r r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
V: Variable based on factory calibration
YES
46
IOUT_OC_FAULT_LIMIT
Value maybe locked
Sets the output overcurrent fault level in A (cannot be changed)
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Function
Exponent Mantissa
Default Value
1 1 1 1 1 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
0 0 1 0 1 0 0 0
YES
47 IOUT_OC_FAULT_RESPONSE
Determines module action in response to an IOU_OC_FAULT_LIMIT or a VOUT
undervoltage (UV) fault
Format
Unsigned Binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r/w
r/w
r/w
r
r r
Function
X X RS
[2]
RS
[1]
RS
[0]
x X X
Default Value
0 0 1 1 1 1 0 0
RS[2:0] – Retry Setting
000 Unit does not attempt to restart
111 Unit goes through normal soft start continuously
Any other value is not acceptable
YES
4A
IOUT_OC_WARN_LIMIT
Value may be locked
Sets the output overcurrent warning level in A
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Function
Exponent Mantissa
Default Value
1 1 1 1 1 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
0 0 1 0 0 1 1 0