PROCESS DATA CHANNEL CONTROL
———
4
20
GEI-100422
Operating modes:
PDC Input channel
PDC Input memory
PDC Output memory
PDC Output channel
sb3_4020
0
1
2
3
0
1
2
3
Process data from Profibus-DP
Process data to Profibus-DP
PAR. 1
PAR. 2
PAR. 3
PAR. 4
PAR. 4
WORD 0
WORD 1
WORD 2
WORD 3
DRIVE PARAMETER
PDC Input
configuration parameter
WORD 0
WORD 1
WORD 2
WORD 3
3
0
1
2
3
0
1
2
PAR. 1
PAR. 2
PAR. 3
PDC Output
configuration parameter
The drive parameters assignment to the Process Data Channel Words is carried
out by means of the index of the parameter itself.
Only drive parameters with a 16-Bit width (1 Word) may be assigned to the
Process Data Channel.