12a analog slimlynx, Open frame: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Analog SlimLynx Open Frame User Manual
Page 12: Design considerations, Safety considerations
GE
Data Sheet
12A Analog SlimLynx
TM
Open Frame: Non-Isolated DC-DC Power Modules
3Vdc –14.4Vdc input; 0.6Vdc to 5.5Vdc output; 12A Output Current
February 19, 2014
©2014 General Electric Corporation. All rights reserved.
Page 12
 
 
Design Considerations
Input Filtering
The 12A Analog SlimLynx
TM
Open Frame module should be
connected to a low ac-impedance source. A highly 
inductive source can affect the stability of the module. An 
input capacitance must be placed directly adjacent to the 
input pin of the module, to minimize input ripple voltage 
and ensure module stability. 
 To minimize input voltage ripple, ceramic capacitors are 
recommended at the input of the module. Figure 37 shows 
the input ripple voltage for various output voltages at 12A 
of load current with 1x22 µF or 2x22 µF ceramic 
capacitors and an input of 12V. 
Figure 37. Input ripple voltage for various output 
voltages with 2x22 µF or 3x22 µF ceramic capacitors at 
the input (12A load). Input voltage is 12V.
Output Filtering
These modules are designed for low output ripple voltage 
and will meet the maximum output ripple specification with 
3x0.047 µF ceramic and 2x47 µF ceramic capacitors at the 
output of the module. However, additional output filtering 
may be required by the system designer for a number of 
reasons. First, there may be a need to further reduce the 
output ripple and noise of the module. Second, the dynamic 
response characteristics may need to be customized to a 
particular load step change. 
To reduce the output ripple and improve the dynamic 
response to a step load change, additional capacitance at 
the output can be used. Low ESR polymer and ceramic 
capacitors are recommended to improve the dynamic 
response of the module. Figure 38 provides output ripple 
information, measured with a scope with its Bandwidth 
limited to 20MHz for different external capacitance values at 
various Vo and a full load current of 12A. For stable 
operation of the module, limit the capacitance to less than 
the maximum output capacitance as specified in the 
electrical specification table. Optimal performance of the 
module can be achieved by using the Tunable Loop
TM
feature
described later in this data sheet.
Figure 38. Output ripple voltage for various output 
voltages with external 2x47 µF, 4x47 µF, 6x47 µF or 8x47 
µF ceramic capacitors at the output (12A load). Input 
voltage is 12V. 
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation 
requirements of the end-use safety agency standards, i.e., 
UL 60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 60950-
1:2006 + A11 (VDE0805 Teil 1 + A11):2009-11; EN 60950-
1:2006 + A11:2009-03. 
 
For the converter output to be considered meeting the 
requirements of safety extra-low voltage (SELV), the input 
must meet SELV requirements. The power module has 
extra-low voltage (ELV) outputs when all inputs are ELV. 
The input to these units is to be provided with a fast acting 
fuse (e.g. ABC Bussmann) with a maximum rating of 20 A in 
the positive input lead
.
 
 
 
 
0
50
100
150
200
250
300
350
400
450
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
1x22uF
2x22 uF
0
10
20
30
40
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
R
ipple
(m
V
p
-p)
Output Voltage(Volts)
2x47uF Ext Cap
4x47uF Ext Cap
6x47uF Ext Cap