GC EUROPE G-aenial Bond User Manual

Page 29

Advertising
background image

29

after TC

before TC

after TC

before TC

100 %

90

80

70

60

50

100 %

90

80

70

60

50

Filtek Z250

GD Posterior

Kalore

G-aenial Posterior

Filtek Z250

GD Posterior

Kalore

G-aenial Posterior

Enamel

Dentin

100 %

90

80

70

60

50

after TC

before TC

G-ænial Bond Technical Manual

Self-etch technique: Class V

The study followed the test set-up as defined page 28:

• Standardised Class V preparations were made in extracted incisors (8 per group).

• The adhesive system GBA 400 (commercially available as G-ænial Bond) was applied in combination with GC Gradia Direct

Posterior according to the manufacturer’s instructions.

Figure 25: amount of "continuous margin" (mQ1) in % of the entire margin length in enamel and dentine in class V restorations,

before and after thermocycling (tc) for G-ænial Bond using the self-etch technique in combination with Gradia Direct. Source:

adapted excerpt from Dr u. Blunck, charité universitätsmedizin Berlin, Germany, 2008

Sem evaluation of the samples after thermocycling demonstrated excellent marginal adaptation of
G-ænial Bond to both enamel and dentine using the self-etch technique (Figure 25), with median
values of 100 % “continuous margin” and mean values of about 97% to 99%.

Etch-and-rinse technique: Class V

The study followed the test set-up as defined page 28:

• Standardised Class V preparations were made in extracted incisors (8 per group).

• The Class V preparations were treated with G-ænial Bond after phosphoric acid etching the entire preparation for 10 s, then

restored with either GC Gradia Direct Posterior, GC G-ænial Posterior, GC Kalore or Filtek Z250 (3M ESPE) using an

incremental technique.

Figure 26: amount of "continuous margin" (mQ1) in % of the entire margin length in enamel (left) and dentine (right) in class

V restorations, before and after thermocycling (tc) for G-ænial Bond along with the etch-rinse-technique, restored with one of

four composite resins. Source: adapted excerpt from Dr u. Blunck, charité universitätsmedizin Berlin, Germany, 2010

Sem evaluation of the marginal adaptation after thermocycling demonstrated a “continuous
margin” in both dentine and enamel, with median and mean values of about 99% to 100 % margin
quality. this result was achieved for all restorations applied with G-ænial Bond after phosphoric
acid etching, irrespective of the composite used for the restoration.