MAINTENANCE

12

charcoal filter (recycling version)

This filter cannot be washed or regenerated. It must be replaced when the

c appears on the

display or at least once every 4 months. The filter saturation alarm has to be activated already

before.

Activation of the alarm signal

• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation

or at a later date.

• Press and hold button

e (Delay) for 5 seconds, until confirmation appears on the display:

C flashes twice – Activated Charcoal Filter saturation alarm ACTIVATED.

C flashes once – Activated Charcoal Filter saturation alarm DEACTIVATED.

RePLAcINg THe cHARcOAL FILTeR

Reset of the alarm signal

• Switch off the hood and the lighting.

• Press the

D-key until the display is unlit.

Replacing of the filter

• Open the comfort panels pulling them downwards.

• Remove the metal grease filters.

• Remove the saturated charcoal filter by releasing

the fixing hooks

• Fit the new filter and fasten it in its correct posi-

tion.

• Put the metal grease filters in their seats.

• Close the comfort panels.

Lighting

LIgHT RePLAceMeNT

20 W halogen light.

• Remove the 2 screws fixing the Lighting support,

and pull it out of from the Hood.

• Extract the lamp from the Support

• Replace with another of the same type, making

sure that the two pins are properly inserted in the

lamp holder socket holes.

• Refit the Support, fixing it in place with the two

screws removed as above.