RecIRcULATION VeRSION AIReOUTLeT

• Insert the connection extension pieces laterally

14.1 in connection 15.

• Insert the Connector

15 into the Support

bracket

7.3 and fix it with a screw.

• Make sure that the outlet of the extension

pieces

14.1 is horizontally and vertically

aligned with the chimney outlets.

• Connect the air outlet connection

15 to the

hood body outlet using either a flexible or

rigid pipe ø 150 mm, the choice of which

is left to the installer.

• Ensure that the activated charcoal filters have

been inserted.

eLecTRIcAL cONNecTION

• Connect the hood to the mains through a

two-pole switch having a contact gap of at

least 3 mm.

• Remove the grease filters (see paragraph

Maintenance) being sure that the connector

of the feeding cable is correctly inserted in

the socket placed on the side of the fan.

cHIMNey ASSeMbLy

Upper exhaust chimney

• Slightly widen the two sides of the upper flue

and hook them behind the brackets

7.2.1,

making sure that they are well seated.

• Secure the sides to the brackets by using the

4 screws

12c (2,9 x 9,5) supplied.

• Make sure that the outlet of the extensions

pieces is aligned with the chimney outlets.

Lower exhaust chimney

• Slightly widen the two sides of the chimney

and hook them between the upper chimney

and the wall, making sure that they are well

seated.

• Fix the lower part laterally to the hood body

using the 2 screws

12c (2,9 x 9,5) supplied.

�����

��

����

���

�����

���

���

���

���

���