Procedure:

1. Click the Event Filter Tab to configure the event filters in the available slots
2. To Add an Event Filter entry, select a free slot and click Add to open the Add

event Filter entry Page. A sample screenshot of Add Event Filter Page is in

seen the screenshot below.

3. In the Event Filter Configuration section,
•

PEF ID displays the ID for configured PEF entry (read-only).

•

In filter configuration, check the box to enable the PEF settings.

•

In Event Severity, select any one of the Event severity from the list.

4. In the Filter Action configuration section,
•

Event Filter Action is a mandatory field and checked by default, which enable

PEF Alert action (read-only).

•

Select any one of the Power action either Power down, Power reset or Power

cycle from the drop down list

•

Choose any one of the configured alert policy number from the drop down

list.

Alert Policy has to be configured - under Configuration->PEF->Alert Policy.

5. In the Generator ID configuration section,
•

Check Generator ID Data option to fill the Generator ID with raw data.

•

Generator ID 1 field is used to give raw generator ID1 data value.

•

Generator ID 2 field is used to give raw generator ID2 data value.

In RAW data field, to specify hexadecimal value prefix with '0x'.