Electrical connection, Gas connection – Hotpoint Ariston PK 755 D GH X-HA User Manual

Page 24

Advertising
background image

24

GB

Front

Hooking position

Back

for top

H=40mm

! Use the hooks contained in the “accessory pack”.

• Where the hob is not installed over a built-in oven, a

wooden panel must be installed as insulation. This must

be placed at a minimum distance of 20 mm from the lower

part of the hob.

Ventilation

To ensure adequate ventilation, the back panel of the cabinet

must be removed. It is advisable to install the oven so that it

rests on two strips of wood, or on a completely flat surface

with an opening of at least 45 x 560 mm (see diagrams).

560 mm

.

45 mm.

! The hob can only be installed above built-in ovens with a

cooling ventilation system.

Electrical connection

Hobs equipped with a three-pole power supply cable are

designed to operate with alternating current at the voltage and

frequency indicated on the data plate (this is located on the

lower part of the appliance). The earth wire in the cable has a

green and yellow cover. If the appliance is to be installed above

a built-in electric oven, the electrical connection of the hob and

the oven must be carried out separately, both for electrical

safety purposes and to make extracting the oven easier.

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load

indicated on the data plate.

The appliance must be directly connected to the mains

using an omnipolar circuit-breaker with a minimum contact

opening of 3 mm installed between the appliance and the

mains. The circuit-breaker must be suitable for the charge

indicated and must comply with current electrical regulations

(the earthing wire must not be interrupted by the circuit-

breaker). The supply cable must not come into contact with

surfaces with temperatures higher than 50°C.

! The installer must ensure that the correct electrical

connection has been made and that it is compliant with

safety regulations.

Before connecting to the power supply, make sure that:

• The appliance is earthed and the plug is compliant with

the law.

• The socket can withstand the maximum power of the

appliance, which is indicated on the data plate.

• The voltage is in the range between the values indicated

on the data plate.

• The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an

authorised technician to replace it. Do not use extension

cords or multiple sockets.

! Once the appliance has been installed, the power supply

cable and the electrical socket must be easily accessible.

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced by

authorised technicians only (see Assistance).

! The manufacturer declines any liability should these safety

measures not be observed.

Gas connection

The appliance should be connected to the main gas

supply in compliance with current national regulations.

Before carrying out the connection, make sure the cooker

is compatible with the gas supply you wish to use G20-

20mbar (Natural Gas).

! Check that the pressure of the gas supply is consistent

with the values indicated in Table 1 (“Burner and nozzle

specifications”). This will ensure the safe operation and

longevity of your appliance while maintaining efficient

energy consumption.

Connection with a rigid pipe (copper or steel)

! Connection to the gas system must be carried out in such a

way as not to place any strain of any kind on the appliance.

There is an adjustable L-shaped pipe fitting on the appliance

supply ramp and this is fitted with a seal in order to prevent

leaks. The seal must always be replaced after rotating the

pipe fitting (seal provided with appliance). The gas supply

pipe fitting is a threaded 1/2 gas cylindrical male attachment.

Connecting a flexible jointless stainless steel pipe to

a threaded attachment

The gas supply pipe fitting is a threaded 1/2 gas cylindrical

male attachment.

These pipes must be installed so that they are never longer

than 2000 mm when fully extended. Once connection has

been carried out, make sure that the flexible metal pipe

does not touch any moving parts and is not compressed.

! Only use pipes and seals that comply with current national

regulations.