6.1.4.6 Rebuilding a RAID set

Rebuilding a RAID set

Rebuilding a RAID set

Rebuilding a RAID set

Rebuilding a RAID set

The utility displays the condition of the RAID set during the POST. When a
RAID set is degraded, you can use the utility to rebuild it.

To rebuild a RAID array:

1.

Enter the Adaptec RAID Configuration Utility following the instructions
in the section “Creating a RAID 0 (Stripe).”

2.

Select A r r a y C o n f i g u r a t i o n U t i l i t y

A r r a y C o n f i g u r a t i o n U t i l i t y

A r r a y C o n f i g u r a t i o n U t i l i t y

A r r a y C o n f i g u r a t i o n U t i l i t y

A r r a y C o n f i g u r a t i o n U t i l i t y from the initial menu, then

press <Enter>.

Check the physical connections of the SATA hard disk drives before you
rebuild a degraded RAID set. Check the system and motherboard user
guide for additional information.

3.

From the main menu, highlight Manage Arrays, then press <Enter> to
display the installed RAID sets.

4.

Highlight the degraded RAID set, then press <Enter> to display the
array properties. The A r r a y S t a t u s

A r r a y S t a t u s

A r r a y S t a t u s

A r r a y S t a t u s

A r r a y S t a t u s shows DEGRADED.