2. Install the power supply cable by loosening the cable

clamp screw and the three wire contact screws
L-N-

.

Connect the wires to the corresponding terminals: the Blue

wire to the terminal marked

(N), the Brown wire to the

terminal marked (L) and the

Yellow/Green wire to the
terminal marked

(see

diagram).

3. Secure the cable by

fastening the clamp screw.

4. Close the cover of the

terminal board.

Connecting the supply cable to the mains

Install a standardised plug corresponding to the load

indicated on the data plate (see table).

The appliance must be directly connected to the mains using

an omnipolar switch with a minimum contact opening of 3

mm installed between the appliance and the mains. The

switch must be suitable for the charge indicated and must

comply with current electrical regulations (the earthing wire

must not be interrupted by the switch). The supply cable

must be positioned so that it does not come into contact

with temperatures higher than 50°C at any point (the back

panel of the oven, for example).

! The installer must ensure that the correct electrical

connection has been performed and that it is fully compliant

with safety regulations.

Before connecting the appliance to the power supply, make

sure that

• The appliance is earthed and the plug is compliant with

the law.

• The socket can withstand the maximum power of the

appliance, which is indicated on the data plate.

• The voltage is in the range between the values indicated

on the data plate.

• The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an

authorised technician to replace it. Do not use extension

cords or multiple sockets.

! Once the appliance has been installed, the power supply

cable and the electrical socket must be easily accessible.

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced by

authorised technicians only (see Assistance).

! The manufacturer declines any liability should these

safety measures not be observed.

N

L

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm
height 32,4 cm
depth 41.5 cm

Volume*

59 l

Dimensions**

width 45.5 cm
height 32,4 cm
depth 41.5 cm

Volume**

62 l

Electrical
connections

voltage: 220 - 240 V~ 50/60 Hz or
50 Hz (see data plate)
maximum power absorbed
2800 W

ENERGY
LABEL

Directive 2002/40/EC on the label
of electric ovens. Standard EN 50304

Declared energy consumption
for Forced convection Class –
heating mode:
ECO.