AVSL 160.457 QTFX2000 User Manual

Page 6

Advertising
background image

User Manual – QTFX-2000

160.457UK

6

Do not use solvents or aggressive detergent to clean the device. Use

a soft and clean cloth.

Do not modify the device or the connected power cord without

authorization.

Use appropriate safety-rope for safety.

Clean the machine regularly using water or smoke cleaning fluid

(160.670)

7. Connect with power supply - The ground wire must be

connected :

Use the plug to connect to the main power supply as following.

Wire

Connection

International signal

Brown

Live

L

Blue

Neutral

N

Yellow /Green

Earth

8. Quick Trouble Shooting :

If the unit is not functioning properly

8.1 Check if main power is on and fuse hasn’t blown

8.2 The remote control is plugged in correctly in to the socket

8.3 Check there is fluid in the tank

8.4 Check that the pipe is pushed down to the bottom of the tank

8.5 Check the correct fluid has been used.

8.6 If there is a block use distilled water or smoke machine cleaning fluid.

User Manual – QTFX-2000

160.457UK

11

14. DMX controlling:

DMX channel

DMX Scale

Detail function

000 - 005

0% Output

CH 1

006 - 255

5% - 100% Output

Dip Switch addressing

To set the DMX address please see the example table below and for more details

visit the QTX website www.qtxlight.com

(Note: 1 = On, 0 = Off)

DIP Switches

DMX

Address

1

2

4

8

16

32

64

128

256

1

1

0

0

0

0

0

0

0

0

2

0

1

0

0

0

0

0

0

0

3

1

1

0

0

0

0

0

0

0

..

..

..

..

..

..

..

..

..

410

0

1

0

1

1

0

0

1

1