Sbr660ctlq, Maximum ratings (per leg), Thermal characteristics – Diodes SBR660CTLQ User Manual

Page 2: Per leg), Electrical characteristics

Advertising
background image

SBR is a registered trademark of Diodes Incorporated.

SBR660CTLQ

Document number: DS36093 Rev. 1 - 2

2 of 6

www.diodes.com

October 2012

© Diodes Incorporated

SBR660CTLQ





Maximum Ratings (Per Leg)

(@T

A

= +25°C, unless otherwise specified.)

Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.

Characteristic Symbol

Value

Unit

Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage

V

RRM

V

RWM

V

RM

60 V

Average Rectified Output Current

(Per Leg)

(Total)

I

O

3
6

A

Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load

I

FSM

80 A

Repettitive Peak Avalanche Power (1

μs, +25 ºC)

P

ARM

10000 W

Non-Repetitive Avalanche Energy
(T

J

= +25°C, I

AS

= 5A, L = 8.5mH)

E

AS

190 mJ



Thermal Characteristics

(Per Leg)

Characteristic Symbol

Value

Unit

Typical Thermal Resistance (per leg) (Note 5)

R

θJC

2 °C/W

Operating and Storage Temperature Range

T

J

, T

STG

-65 to +150

ºC



Electrical Characteristics

(Per Leg)

(@T

A

= +25°C, unless otherwise specified.)

Characteristic Symbol

Min

Typ

Max

Unit

Test

Condition

Leakage Current (Note 6)

I

R

-
-

-

5

0.3

12

mA

V

R

= 60V, T

J

= +25ºC

V

R

= 60V, T

J

= +125ºC

Forward Voltage Drop

V

F

- -

0.57

V

I

F

= 3A, T

J

= +25ºC

Notes:

5. Device mounted on Polymide substrate, 125mm

2

Copper pad, double-sided, PC Board.

6. Short duration pulse test used to minimize self-heating effect.




0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

P

,

P

O

WE

R

DI

SSI

P

A

T

IO

N

(W

)

D

0

1

2

3

4

5

6

I

, AVERAGE FORWARD CURRENT (A)

F(AV)

Figure 1 Forward Power Dissipation

0.0001

0.001

0.01

0.1

1

0

100

200

300

400

500

600

700 800

Figure 2 Typical Forward Characteristics

V , INSTANTANEOUS FORWARD VOLTAGE (mV)

F

I

, INS

T

A

NT

A

NEOUS

F

O

RW

ARD

C

URRENT

(

A

)

F

T = 25°C

A

T = 125°C

A

T = 150°C

A

T = 85°C

A

T = -55°C

A



Advertising