New p roduct, Electrical characteristics – Diodes PDU620 User Manual

Page 2

Advertising
background image

DS30760 Rev. 2 - 2

2 of 4

PDU620

PowerDI is a trademark of Diodes Incorporated.

www.diodes.com

NEW

P

RODUCT

I

,

INST

ANT

A

NEOUS

FOR

W

A

RD

CURRENT

(A)

F

V , INSTANTANEOUS FORWARD VOLTAGE (V)

Fig. 1 Typical Forward Characteristics

F

1m

10m

100m

1

10

100

0

0.4

0.8

1.2

0.2

0.6

1

1.4

T = -65°C

j

T = 175°C

j

T = 150°C

j

T = 125°C

j

T = 85°C

j

T = 25°C

j

0

40

80

120

200

V , INSTANTANEOUS REVERSE VOLTAGE (V)

Fig. 2 Typical Reverse Characteristics

R

160

0.1

1

10

100

1,000

0.001

0.01

T = 175°C

j

T = -65°C

j

T = 25°C

j

T = 150°C

j

T = 85°C

j

T = 125°C

j

C,

T

O

T

A

L

C

AP

ACIT

ANCE

(pF)

T

V , REVERSE VOLTAGE (V)

Fig. 3 Typical Total Capacitance vs. Reverse Voltage

R

0

50

100

150

200

250

300

350

400

0

10

20

30

f = 1MHz

0

1.5

3

4.5

7.5

6

0

25

50

75

125

100

150

175

I,

D

C

F

O

R

W

ARD

CURRENT

(A)

F

T , AMBIENT TEMPERATURE (°C)

Fig. 4 DC Forward Current Derating

A

Note 3

Note 2

Note 4

Electrical Characteristics

@ T

A

= 25

°C unless otherwise specified

Characteristic

Symbol

Value

Unit

Test Condition

Minimum Reverse Breakdown Voltage (Note 5)

V

(BR)R

200

V

I

R

= 5

mA

Maximum Forward Voltage

V

FM

0.940
0.860
0.975
0.895

V

I

F

= 6A, T

S

= 25

°C

I

F

= 6A, T

S

= 150

°C

I

F

= 8A, T

S

= 25

°C

I

F

= 8A, T

S

= 150

°C

Maximum Reverse Leakage Current (Note 5)

I

RM

5

500

mA

T

S

= 25

°C, V

R

= 200V

T

S

= 100

°C, V

R

= 200V

Maximum Reverse Recovery Time

t

rr

25

ns

I

F

= 0.5A, I

R

= 1.0A

I

RR

= 0.25A (See figure 7)

Notes:

5. Short duration test pulse used to minimize self-heating effect.

Advertising