Application information, Minimum copper area characteristics – Diodes ZXMS6001N3 User Manual

Page 6

Advertising
background image

ZXMS6001N3

Issue 1 - January 2008

6

www.zetex.com

© Zetex Semiconductors plc 2008

Application information

The current-limit protection circuitry is designed to de-activate at low Vds to prevent the load
current from being unnecessarily restricted during normal operation. The design max DC
operating current is therefore determined by the thermal capability of the package/board
combination, rather than by the protection circuitry (see graph page 8 'typical output
characteristic'). This does not compromise the products ability to self protect at low V

DS

.

The overtemperature protection circuit trips at a minimum of 150°C. So the available package
dissipation reduces as the maximum required ambient temperature increases. This leads to the
following maximum recommended continuous operating currents.

Minimum copper area characteristics

For minimum copper condition as described in note (c)

Max Ambient Temperature T

A

Maximum continuous current

V

IN

=5V

25°C at Vin=5V

720

70°C at Vin=5V

575

85°C at Vin=5V

520

125°C at Vin=5V

320

1

10

100

1m

10m

100m

1

1ms

Single Pulse

T

amb

=25°C

R

DS(on)

Limited

10ms

100ms

1s

Safe Operating Area

I

D

D

rain C

urre

nt

(

A

)

V

DS

Drain-Source Voltage (V)

DC

0

20

40

60

80

100

120

140

160

0.0

0.2

0.4

0.6

see note (c) - Minimum Copper

Derating Curve

Temperature (°C)

Max

P

ow

er D

iss

ip

at

ion (W

)

100µ

1m

10m 100m

1

10

100

1k

0

50

100

150

200

T

amb

=25°C

Transient Thermal Impedance

D=0.5

D=0.2

D=0.1

Single Pulse

D=0.05

Thermal Re

s

is

tan

ce

C/

W

)

Pulse Width (s)

100µ

1m

10m 100m

1

10

100

1k

1

10

100

Single Pulse

T

amb

=25°C

Pulse Power Dissipation

Pulse Width (s)

Maximu

m

P

o

w

er (

W

)

Advertising