Typical Characteristics

(cont.)

















Power Dissipation

The maximum allowable power dissipation of the device for
normal operation (P

MAX

), is a function of the package junction to

ambient thermal resistance (

θ

JA

), maximum junction temperature

(T

JMAX

), and ambient temperature (T

AMB

), according to the

expression:

P

MAX

= (T

JMAX

– T

AMB

) /

θ

JA


The device power dissipation, P

D

is given by the expression:

P

D

= I

OUT

(V

IN

-V

OUT

) W

Application Information

The following text describes how to scale a load current
to an output voltage.

V

SENSE

= V

IN

- V

LOAD

V

OUT

= 0.01 x V

SENSE

x R

OUT

1


E.g.

A 1A current is to be represented by a 100mV output
voltage:

1) Choose the value of R

SENSE

to give 50mV >

V

SENSE

> 500mV at full load.

For example V

SENSE

= 100mV at 1.0A.

R

SENSE

= 0.1/1.0 => 0.1

Ω.

2) Choose R

OUT

to give V

OUT

= 100mV, when

V

SENSE

= 100mV.

Rearranging

1

for Rout gives:

R

OUT

= V

OUT

/(V

SENSE

x 0.01)

R

OUT

= 0.1 / (0.1 x 0.01) = 100