The following lines describe how to scale a load
current to an output voltage.

V

sense

= V

in

- V

load

V

out

= 0.01 x V

sense

x R

out

1

E.g.

A 1A current is to be represented by a 100mV output
voltage:

1)Choose the value of R

sense

to give 50mV > V

sense

>

500mV at full load.

For example V

sense

= 100mV at 1.0A. R

sense

= 0.1/1.0

=> 0.1 ohms.

2)Choose R

out

to give V

out

= 100mV, when V

sense

=

100mV.

Rearranging

1

for R

out

gives:

R

out

= V

out

/(V

sense

x 0.01)

R

out

= 0.1 / (0.1 x 0.01) = 100

Ω

TYPICAL CIRCUIT APPLICATION

POWER DISSIPATION

The maximum allowable power dissipation of the
device for normal operation (Pmax), is a function of
the package junction to ambient thermal resistance
(

θja), maximum junction temperature (Tjmax), and

ambient temperature (Tamb), according to the
expression:

P

max

= (Tj

max

– T

amb

) /

θ

ja

The device power dissipation, P

D

is given by the

expression:

P

D

=I

out

.(V

in

-V

out

) Watts

Where R

load

represents any load including DC motors,

a charging battery or further circuitry that requires
monitoring, R

sense

can be selected on specific

requirements of accuracy, size and power rating.