© Zetex Semiconductors plc 2005

A 1 ampere load current is to be measured into a battery. The output signal required to an over
current controller needs to be 3.3V. What is a suitable value of R

out

and what will the error due

to the supply current be?

V

in

= 5.0V - 9.0V

I

load

= 1.0A

Output signal required: 3.3V

Figure 1

ZXCT1011 to measure a 1.0 A load current

To obtain the highest accuracy, choose the of R

sense

to give 100mV:

R

sense

= 0.1/1.0 = 0.1

The transconductance using a 120

⍀ resistor will be 10mA/V.

Choose R

out

to give V

out

= 3.3V, when V

sense

= 100mV

Rearranging equation 1 without the offset error gives:

R

out

= (V

out

x R

shunt

) / (1.2 x I

Load

x R

sense

)

R

out

= 3.3k

Now consider the offset error for this resistor:

Offset due to supply current = R

out

x 4x10

-6

µA = 13.2mV = 0.4%

V

sense+

ZXCT

1011

sense-

V

V

in

R

sense

I

load

= 1A

I

out

2

5

4

R

R

shunt

3

out

R

load

R

shunt

120R

3.3V

= 5.0V - 9.0V