Applications Information

(cont.)

The following lines describe how to scale a load current to an output voltage.

V

SENSE

= R

SENSE

* I

LOAD

equation (1)


I

OUT

= 10mA/V x V

SENSE

equation (2)


V

OUT

= I

OUT

x R

OUT

equation (3)

Design example

In the circuit below a 1A current is to be represented by a 100mV output voltage (V

OUT

):


A) To be within recommended values choose the value of R

SENSE

to give:


50mV > V

SENSE

> 200mV at full load.


For example set V

SENSE

= 100mV at 1.0A.


From equation (1)

R

SENSE

= 0.1V/1.0A = 0.1


B) Now choose R

OUT

to give:


V

OUT

= 100mV, when V

SENSE

= 100mV.


From equation (2)

I

OUT

= 10mA/V x 0.1 = 1mA


Rearranging equation (3) for R

OUT

gives:


R

OUT

= V

OUT

/I

OUT

= 0.1/0.001 = 100

ZXCT1012

R

SENSE

V

IN

V

OUT

R

OUT

R

LOAD

SENSE+

SENSE-

OUT

GND

= 0.1 / (0.1 x 0.01) = 100

Typical Circuit Application


Where R

LOAD

represents any load including DC motors, a charging battery or further circuitry that requires monitoring, R

SENSE

can be selected on specific requirements of accuracy, size and power rating.