Zxre160 new prod uc t, Electrical characteristics – Diodes ZXRE160 User Manual

Page 5

Advertising
background image

ZXRE160

Document number: DS35688 Rev. 2 - 2

5 of 15

www.diodes.com

June 2012

© Diodes Incorporated

ZXRE160

NEW PROD

UC

T

A Product Line of

Diodes Incorporated



Electrical Characteristics

(@T

A

= +25°C, V

DD

= 3V, unless otherwise specified.)

T

A

= +25°C, V

IN

= 3.3V, V

OUT

= V

FB

, I

OUT

= 5mA, unless otherwise specified.) (Note 4)

Symbol Parameter

Conditions

Min Typ Max Units

V

FB

Feedback voltage

ZXRE160A

0.597 0.6 0.603

V

ZXRE160

0.594 0.6 0.606

T

A

= 0°C to +85°C

ZXRE160A 0.595

0.605

ZXRE160 0.592

0.608

T

A

= -40°C to +85°C

ZXRE160A 0.594

0.606

ZXRE160 0.591

0.609

T

A

= -40°C to +125°C

ZXRE160A 0.593

0.607

ZXRE160 0.590

0.610

FB

LOAD

Feedback pin load

regulation

I

OUT

= 1 to 15mA

3.8

6

mV

T

A

= -40 to +125°C

10

FB

LINE

Feedback pin line

regulation

V

IN

= 2V to 18V

0.3 1

mV

V

IN

= 2.2V to 18V

T

A

= -40 to +125°C

1.5

FB

OVR

Output voltage

regulation

V

OUT

= 0.2V to 18V,

I

OUT

= 1mA

(Ref. Figure 1)

1

mV

T

A

= -40 to +125°C

1.5

I

FB

FB input bias current

V

IN

= 18V

-45

nA

T

A

= -40 to +125°C

-200 0

V

FB

= 0.7V

-50 50

I

IN

Input current

V

IN

= 2V to 18V

I

OUT

= 0.3mA

0.35

0.7

mA

V

IN

= 2.2V to 18V

T

A

= -40 to +125°C

1

V

IN

= 2V to 18V

I

OUT

= 10mA

0.48

1

mA

V

IN

= 2.2V to 18V

T

A

= -40 to +125°C

1.5

V

IN

= 18V, I

OUT

= 0.3mA

V

FB

= 0.7V

3

I

OUT(LK)

OUT leakage current

V

IN

= 18V,

V

OUT

= 18V,

V

FB

=0V

0.1

µA

T

A

= +125°C

1

Z

OUT

Dynamic Output

Impedance

I

OUT

= 1 to 15mA

f < 1kHz

0.25

0.4

Ω

T

A

= -40 to +125°C

0.6

PSRR

Power supply rejection

ratio

F = 300kHz

V

AC

= 0.3V

PP

>45 dB

BW

Amplifier Unity Gain

Frequency

Ref: Figure 2

600 kHz

G

Amplifier

Transconductance

5000 mA/V

Note:

4. Production testing of the device is performed at +25

°C. Functional operation of the device and parameters specified over the operating temperature

range are guaranteed by design, characterization and process control.






Advertising