Absolute maximum ratings, Thermal resistance, Recommended operating conditions – Diodes AP65200 User Manual

Page 3

Advertising
background image

AP65200

Document number: DS35548 Rev. 6 - 2

3 of 18

www.diodes.com

January 2014

© Diodes Incorporated

NEW PROD

UC

T

AP65200



Absolute Maximum Ratings

(Note 4) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter

Rating Unit

V

IN

Supply Voltage

-0.3 to +20

V

V

SW

Switch Node Voltage

-1.0 to V

IN

+0.3

V

V

BS

Bootstrap Voltage

V

SW

-0.3 to V

SW

+6.0

V

V

FB

Feedback Voltage

-0.3V to +6.0

V

V

EN

Enable/UVLO Voltage

-0.3V to +6.0

V

V

COMP

Comp Voltage

-0.3V to +6.0

V

T

ST

Storage Temperature

-65 to +150

°C

T

J

Junction Temperature

+160

°C

T

L

Lead Temperature

+260

°C

ESD Susceptibility (Note 5)

HBM

Human Body Model

1.5

kV

MM Machine

Model

150 V

Notes:

4. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may

be affected by exposure to absolute maximum rating conditions for extended periods of time.

5. Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when

handling and transporting these devices.



Thermal Resistance

(Note 6)

Symbol Parameter

Rating

Unit

θ

JA

Junction to Ambient

SO-8 119

°C/W

SO-8EP 40

MSOP-8EP 48

U-DFN2626-10 53

θ

JC

Junction to Case

SO-8 31

°C/W

SO-8EP 9

MSOP-8EP 9

U-DFN2626-10 8.5

Note:

6. Test condition: SO-8: Device mounted on 1"x1" FR-4 substrate PCB, 2oz copper, with minimum recommended pad layout.

SO-8EP: Device mounted on 2"x2" FR-4 substrate PCB, 2oz copper, with minimum recommended pad layout and thermal vias to bottom layer GND

plane.

MSOP-8EP: Device mounted on 2"x2" FR-4 substrate PCB, 2oz copper, with minimum recommended pad layout.

U-DFN2626-10: Device mounted on 2"x2" FR-4 substrate PCB, 2oz copper, with minimum recommended pad layout.



Recommended Operating Conditions

(Note 7) (@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Min

Max

Unit

V

IN

Supply Voltage

4.7

18.0 V

T

A

Operating Ambient Temperature Range

-40

+85 °C

Note:

7. The device function is not guaranteed outside of the recommended operating conditions.















Advertising