Recommended operating conditions – Diodes AP2156 User Manual

Page 3

Advertising
background image

AP2146/AP2156

Document number: DS31813 Rev. 3 - 2

3 of 17

www.diodes.com

March 2013

© Diodes Incorporated

AP2146/AP2156

Absolute Maximum Ratings

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Rating

Unit

ESD HBM

Human Body Model ESD Protection

6

kV

ESD MM

Machine Model ESD Protection

300

V

V

IN

Input Voltage

6.5

V

V

OUT

Output Voltage

V

IN

+0.3

V

V

EN ,

V

FLG

Enable Voltage

6.5

V

I

LOAD

Maximum Continuous Load Current

Internal Limited

A

T

J(MAX)

Maximum Junction Temperature

150

°C

T

ST

Storage Temperature Range (Note 4)

-65 to +150

°C

Note:

4. UL Recognized Rating from -30°C to +70°C (Diodes qualified

T

ST

from -65°C to +150°C)

Recommended Operating Conditions

(@T

A

= +25°C, unless otherwise specified.)

Symbol Parameter Min

Max

Units

V

IN

Input voltage

2.7

5.5

V

I

OUT

Output Current

0

500

mA

V

IL

Low-Level Input Voltage on EN or EN

2

V

IN

V

V

IH

High-Level Input Voltage on EN or

EN

0 0.8

V

T

A

Operating Ambient Temperature

-40

+85

C












































Advertising