DUAL 1A LOW DROPOUT POSITIVE REGULATOR

AP1120 Rev. 2

4 of 7

FEBRUARY 2009

www.diodes.com

©

Diodes Incorporated

Absolute Maximum Ratings


Symbol

Parameter

Rating

Unit

V

IN

DC Supply Voltage

-0.3 to 18 V

V

P

D

Power Dissipation

Internally Limited

T

ST

Storage Temperature

-65 to +150

o

C

T

OP

Operating Junction Temperature Range

0 to +150

o

C


Electrical Characteristics

(Under Operating Conditions)


Parameter

Conditions

Min

Typ.

Max

Unit

Output Voltage

AP1120(B) - V

OUT1

I

OUT

= 10mA, T

A

= 25

o

C,

4.8V

V

IN

12V

3.235 3.300 3.365 V

AP1120 - V

OUT2

I

OUT

= 10mA, T

A

= 25

o

C,

4V

V

IN

12V

2.450 2.500 2.550 V

AP1120B - V

OUT2

I

OUT

= 10mA, T

A

= 25

o

C,

4V

V

IN

12V

1.764 1.800 1.836 V

Line Regulation

I

O

=10mA,V

OUT

+1.5V<V

IN

<12V, T

A

=25

o

C

0.2

%

Load Regulation

AP1120 series
V

OUT1

V

IN

= 5V, 0

I

OUT

1A,

T

A

=25

o

C (Note 3, 4)

26

33

mV

AP1120 series
V

OUT2

V

IN

=4V, 0mA<Io<1A,

T

A

=25

o

C (Note 3, 4)

20

25

mV

Dropout Voltage
(V

IN

-V

OUT

)

I

OUT

= 1A,

ΔV

OUT

=0.1%V

OUT

1.3

1.4 V

Current Limit

(V

IN

-V

OUT

) = 5V

1. 1

A

Minimum Load Current 0

o

C

Tj

125

o

C (Note 5)

5

10

mA

Thermal Regulation

T

A

=25

o

C, 30ms pulse

0.008

0.04

%/W

Ripple Rejection

F=120Hz,C

OUT

=25uF Tantalum, I

OUT

=1A

60

70

dB

Temperature Stability

I

O

=10mA

0.5

%

JA

θ

Thermal Resistance

Junction-to-Ambient (No
heat sink; No air flow)

SOP-8L: Control Circuitry/Power Transistor
(Note 6)
CH1 or CH2 only
CH1 & CH2 and PD1=PD2

50
45

O

C/W

JC

θ

Thermal Resistance

Junction-to-Case

SOP-8L: Control Circuitry/Power Transistor
(Note 6)
CH1 or CH2 only
CH1 & CH2 and PD1=PD2

20
12

O

C/W

Notes: 3. See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are
measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output
lead = 1/18” from the package.
4. Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by

the input/output differentially and the output current. Guaranteed maximum power dissipation will not be available over the
full input/output range.

5. Quiescent current is defined as the minimum output current that requires maintaining regulation. At 12V input/output

differential the device is guaranteed to regulate if the output current is greater than 10mA.

6. Vout1 and Vout2 are connected to the PCB copper area 5.5mm*5.5mm separately. If you need large PD or lower Tc & Tj,

please connect to the large copper area >> 5.5mm*5.5mm (like 10mm*10mm).