Apm8601, New prod uc t absolute maximum ratings, Thermal resistance – Diodes APM8601 User Manual

Page 4: Recommended operating conditions

Advertising
background image

APM8601

DUAL CHANNEL SINGLE CELL LINEAR LITHIUM BATTERY

CHARGER WITH 28V OVP and PROGRAMMABLE CHARGE

TIMER

APM8601

Document number: DS35138 Rev. 1 - 2

4 of 14

www.diodes.com

December 2010

© Diodes Incorporated

NEW PROD

UC

T

Absolute Maximum Ratings

Symbol

Parameter

Rating

Unit

DC, USB to GND

-0.3 to 28V

V

BAT, CT, SETI, USEL, THM,

FLT

,

CHG

,

POK

,

EN

to GND

-0.3 to 6V

V

ESD Susceptibility (Note 2)

HBM Human

Body

Model

2

kV

MM Machine

Model

200

V

Note:

2. Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be

taken when handling and transporting this device.

Thermal Resistance

(Note 3)

Symbol

Parameter

Rating

Unit

θ

JA

Junction to Ambient

40

°C/W

Note:

3. Test condition for DFN3030-10: Device mounted on FR-4 2-layer board, 2oz copper, with minimum recommended pad on top layer and 6 vias to

bottom layer 1.0”x1.5” ground plane.

Recommended Operating Conditions

(Note 4)

Symbol

Parameter

Rating

Unit

Ambient Temperature Range

-40 to +85

°C

Input Supply Voltage

4.15 to 7.00

V

I

CHARGE

Typical Charge Current

0.1 to 1.0

A

Note:

4. The device function is not guaranteed outside of the recommended operating conditions.













Advertising