150mA RF ULDO REGULATOR AP2202

Data Sheet

5

Jul. 2011 Rev. 2. 2

BCD Semiconductor Manufacturing Limited

Parameter

Symbol

Value

Unit

Supply Input Voltage

V

IN

15

V

Enable Input Voltage

V

EN

15

V

Power Dissipation

P

D

Internally Limited (Thermal Protection)

W

Lead Temperature (Soldering, 10sec)

T

LEAD

260

o

C

Junction Temperature

T

J

150

o

C

Storage Temperature

T

STG

-65 to 150

o

C

ESD (Machine Model)

200

V

Thermal Resistance (No Heatsink)

θ

JA

SOT-23-5

200

o

C/W

SOT-89

165

Note 1:

Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device.

These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated
under "Recommended Operating Conditions" is not implied. Exposure to "Absolute Maximum Ratings" for extended periods
may affect device reliability.

Absolute Maximum Ratings (Note 1)

Parameter

Symbol

Min

Max

Unit

Supply Input Voltage

V

IN

2.5

13.2

V

Enable Input Voltage

V

EN

0

13.2

V

Operating Junction Temperature

T

J

-40

125

o

C

Recommended Operating Conditions