600mA LOW DROPOUT LINEAR REGULATOR AP1117M

Data Sheet

600mA LOW DROPOUT LINEAR REGULATOR AP2317

5

Mar. 2007 Rev. 1. 6

BCD Semiconductor Manufacturing Limited

Recommended Operating Conditions

Note 1:

Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the

device.

These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated
under "Recommended Operating Conditions" is not implied. Exposure to "Absolute Maximum Ratings" for extended periods
may affect device reliability.
Note 2: Absolute maximum ratings indicate limits beyond which damage to the component may occur. Electrical specifica-
tions do not apply when operating the device outside of its operating ratings. The maximum allowable power dissipation is a
function of the maximum junction temperature, T

J(max),

the junction-to-ambient thermal resistance,

θ

JA,

and the ambient tem-

perature, T

A.

The maximum allowable power dissipation at any ambient temperature is calculated using: P

D(max)

=(T

J(max)

-

T

A

)/

θ

JA.

Exceeding the maximum allowable power dissipation will result in excessive die temperature, and the regulator will

go into thermal shutdown.

Parameter

Symbol

Value

Unit

Input Voltage

V

IN

15

V

Operating Junction Temperature

T

J

150

o

C

Storage Temperature Range

T

STG

-65 to 150

o

C

Lead Temperature (Soldering, 10sec)

T

LEAD

260

o

C

Thermal Resistance (Note 2)

θ

JA

SOT-223

120

o

C/W

SOT-89-3

165

TO-263-3

80

ESD (Human Body Model)

ESD

3500

V

ESD (Machine Model)

ESD

400

V

Parameter

Symbol

Min

Max

Unit

Input Voltage

V

IN

12

V

Operating Junction Temperature Range

T

J

-40

125

o

C

Absolute Maximum Ratings (Note 1)