Ap7335a, New prod uc t absolute maximum ratings, Recommended operating conditions – Diodes AP7335A User Manual

Page 3

Advertising
background image

AP7335A

300mA, LOW QUIESCENT CURRENT, FAST TRANSIENT

LOW DROPOUT LINEAR REGULATOR

AP7335A

Document number: DS35267 Rev. 2 - 2

3 of 12

www.diodes.com

October 2011

© Diodes Incorporated

NEW PROD

UC

T

Absolute Maximum Ratings

Symbol

Parameter

Ratings

Unit

ESD HBM

Human Body Model ESD Protection

2000

V

ESD MM

Machine Model ESD Protection

200

V

V

IN

Input Voltage

6.5

V

OUT, EN Voltage

V

IN

+ 0.3

V

Continuous Load Current per Channel

Internal Limited

T

ST

Storage Temperature Range

-65 to 150

°C

T

J

Maximum Junction Temperature

150

°C

Stresses greater than the 'Absolute Maximum Ratings' specified above, may cause permanent damage to the device. These are stress ratings only; functional
operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be affected by
exposure to absolute maximum rating conditions for extended periods of time.

Recommended Operating Conditions

Symbol

Parameter

Min

Max

Unit

V

IN

Input voltage (Note 3)

2 (Note 3)

6

V

I

OUT

Output Current (Note 2)

0

300

mA

T

A

Operating Ambient Temperature

-40

85

°C

Notes:

2. The device maintains a stable, regulated output voltage without a load current.

3.

V

IN(MIN)

= 5.5V for 5.0V, V

OUT

at 300mA I

OUT









Advertising