HIGH EFFICIENCY 1X/1.5X/2X CHARGE PUMP

FOR WHITE LED APPLICATIONS

AP3156 Rev. 1

11 of 15

SEPTEMBER 2009

www.diodes.com

©

Diodes Incorporated



SDI Command Timing Protocol


For the SDI command to be successfully received by the AP3156, all SDI timing specifications must be satisfied.

When no command is being sent, the SDI pin should be held High. If the SDI pin goes Low and stays Low for a time length between
T

SLO

(min) and T

SLO

(max) and then goes High and stays High for the length between T

SHI

(min) and T

SHI

(max), one falling edge is

registered by the AP3156. The total number of falling edges registered before the SDI pin is held High for longer than the maximum
separation time T

SEP(max)

identifies the command that has been received by the AP3156. The next series of falling edges before

another separation time of T

SEP

represents the next command. In other words, the AP3156 counts the number of consecutive falling

edges on the SDI pin and a different number represents a different command.

Each command is executed after it is successfully received. If at any time the SDI pin is held Low for longer than the maximum chip
disable time T

OFF(max)

, then the AP3156 will be turned off and enters the shutdown mode. Setting the SDI pin switching from Low to High

will re-enable the AP3156 and leave the shutdown mode. If the SDI pin is held on for a time duration over T

SEP

, then an end of a

sequence (EOS) occurs with a number of pulse conformed to specified timing.

A valid dual-sequence command occurs when one valid sequence is defined as an instruction, and the other is defined as data. Both
sequences have number of pulses less than 33. Also, a valid single-sequence command occurs when the sequence has number of
pulses greater than 32.

Channel 1 in

dimming control

T

SLO

T

SHI

T

SEP

SDI

Channel D2

1

2

9

10

8

2

1

Second Sequence

Channel D3

Channel D4

Channel D1

Channel Selection

Current Setting

Set Channel 1 to current level 2.

Channel D5

Channel D6

Channel 2 in

dimming control

Set Channel 2 to current level 2.

Channel 3 in

dimming control

Set Channel 3 to current level 2.

Channel 4 in

dimming control

Set Channel 4 to current level 2.

Channel 5 in

dimming control

Set Channel 5 to current level 2.

Channel 6 in

dimming control

Set Channel 6 to current level 2.

First Sequence

T

SEP

Figure 1: Dimming Control Selection (Dual-Sequence Command)





Serial Digital Interface