AP8800

Document number: DS31764 Rev. 7 - 2

4 of 13

www.diodes.com

August 2012

© Diodes Incorporated

AP8800


Application Information

AP8800 Operation

The AP8800 is a hysteretic LED current switching regulator sometimes known as an equal ripple switching regulator. In normal operation, when

voltage is applied at +V

IN

(See

Figure 1), the AP8800 internal switch is turned on. Current starts to flow through sense resistor R

1

, inductor L1,

and the LEDs. The current ramps up linearly, and the ramp rate is determined by the input voltage +V

IN

, and the inductor L1 (See Figure 2).



Figure 1 Typical Configuration

Figure 2 Typical Switching Waveform

This rising current produces a voltage ramp across R

SET

. The internal circuit of the AP8800 senses the voltage across R

SET

and applies a

proportional voltage to the input of the internal comparator.

When this voltage reaches an internally set upper threshold, the internal switch is turned off. The inductor current continues to flow through R

SET

,

L1, the LEDs and the schottky diode D1, and back to the supply rail, but it decays, with the rate of decay determined by the forward voltage drop

of the LEDs and the schottky diode.

This decaying current produces a falling voltage at R

SET

, which is sensed by the AP8800. A voltage proportional to the sense voltage across

R

SET

is applied at the input of the internal comparator. When this voltage falls to the internally set lower threshold, the internal switch is turned on

again. This switch-on-and-off cycle continues to provide the average LED current set by the sense resistor R

SET,

with a switching current

determined by the input voltage and LED chain voltage.

In normal operation the off time is relatively constant (determined mainly by the LED chain voltage) with only the on-time varying as the input

voltage changes. At duty cycles up to around 80% the ramp of the LED/switch current is very linear; however, as the duty cycle approaches 95%

the LED current ramp starts to become more exponential. This has two effects:

1.

The overall on time starts to increase lowering the overall switching frequency.

2.

The average LED current starts to increase – which may impact accuracy.