Ap8801, 500ma led step-down converter, Pin descriptions – Diodes AP8801 User Manual

Page 2: Functional block diagram, Absolute maximum ratings

Advertising
background image

AP8801

500mA LED STEP-DOWN CONVERTER

AP8801

Document number: DS31765 Rev. 7 - 2

2 of 14

www.diodes.com

June 2012

© Diodes Incorporated

Pin Descriptions

Pin Name

Functions

SW

Switch Pin. Connect inductor/freewheeling diode here, minimizing track length at this pin to reduce EMI.

GND GND

pin

SET

Set Nominal Output Current Pin. Configure the output current of the device.

CTRL

Dual Function Dimming Control Pin.

• Input voltage of 0.2V or lower forces the device into low current standby mode and shuts off the output.
• A PWM signal (driven by an open-drain/collector source) allows the output current to be adjusted over a wide

range up to 100%.

• An analog voltage between 0.3V and 2.5V adjusts the output current between 25% and 200% of the current set

by 0.2V/R

S

.

The input impedance is about 50k

Ω, and if the pin is left open V

CTRL

= V

REF

V

IN

Input Supply Pin. Must be locally bypassed.

NC No

connection


Functional Block Diagram

Fig. 1 Block Diagram


Absolute Maximum Ratings

Symbol

Parameter

Rating

Unit

V

IN

V

IN

pin voltage

-0.3 to +50

V

V

SW

SW voltage

-0.3 to +50

V

V

CTRL

CTRL Pin Input Voltage

-0.3 to +6

V

V

SENSE

SET Voltage

+0.3 to -5

V

T

J

Junction Temperature

150

o

C

T

LEAD

Lead Temperature Soldering

300

o

C

T

ST

Storage Temperature Range

-65 to +150

o

C

Caution:

Stresses greater than the 'Absolute Maximum Ratings' specified above, may cause permanent damage to the device. These are stress ratings only;

functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may

be affected by

exposure to absolute maximum rating conditions for extended periods of time.

Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when

handling and transporting these devices.